E-mail
us
PATTERSON
Industries Canada "The Process
Equipment People" designs, engineers and manufactures Evaporators to customer's
specifications and process parameters. PATTERSON's
Shell & Tube type Heat Exchangers and Condensers are
built to meet the requirements of the ASME Code, Section VIII, Division I and in
accordance with the Tubular Exchanger Manufacturers Association (TEMA) standards.
Mechanical and Thermal design utilizes computerized technology that allows for the optimum
performance while considering cost and available space.
PATTERSON's manufacturing
facility together with full transportation access allows for the machining and fabricating
of Heat Exchangers and Condensers from most of the more common materials, in sizes up to
15 feet (4.5 m) in diameter and up to 100 tonnes. For those large and/or heavy units,
equipment having special design requirements, high pressure operating conditions or
unusual materials of constructions; these are the application where PATTERSON's experience
will benefit the end-user.
Applications:
- Concentration of bi-products from food and feed industries
- Concentration of waste streams from food and feed industries
- Concentration of waste streams from steel mills and metal working industries
- Concentration of waste streams from chemical industries
Design Features:
PATTERSON Evaporators are computer designed for optimum performance at a minimum cost.
PATTERSON can either build to your designs or develop the equipment requirements from
your process parameters.
Units are designed, inspected and tested in our manufacturing facility to meet ASME
Code, Section VIII, Division I and TEMA "B" "C" and "R"
Standards.
Manufactured from a full range of Low Temperature and Regular Carbon Steels, Stainless
Steels, Inconels, Incoloys, Nickels, Hastelloys and Clad Materials.
Complete design, engineering and manufacturing under one roof with our modern
state-of-the-art, machining centers, automated tube to tubesheet
welding, weld preparation grinding equipment and automated welding systems.
Units can be individually designed to customer's material specifications and process
parameters. Complete the Evaporator Specification Sheet and submit by e-mail to
PATTERSON for quotation.
|
 |
Control
Systems
Please note: PATTERSON
has in-house expertise to design and supply operating control
systems for all of our process equipment, whether it is a simple
start/stop with cycle time or complex multi-stage systems
executing recipes or formulas and communicating with existing
plant control systems.
|
|

Close up of Control Box with
stop/start, jog/run and 0-12 hr timer.
|
|
Control Panel Overview including
HMI Touch Screen.
|
|

Close-up of Inside of Control Panel
with PLC and Variable Frequency Motor Controllers.
|
|
FOR SALE
PATTERSON
MOBILE PILOT EVAPORATION PLANT
WITHOUT PUMPS & INSTRUMENTATION CONSISTING OF THE FOLLOWING:
- Falling Film/Forced Circulation
14" diameter x 180" long, 304 stainless steel shell
side, 316 stainless steel tube side, type BEM Heat Exchanger
with interchangeable channels (can be used horizontally or
vertically), 2" O.D. tubing size, 94 sq.ft (8.75 sq.m)
heat transfer area.
Shell
Tube
Design
Pressure
75
psig
75 psig
Design
Temperature
320ºF
320ºF
Min. Design Metal
Temp 32ºF
32ºF
At
Pressure:
75
psig
75 psig
- Condenser 8 x 180 straight side,
Type BEM Heat Exchanger, 304 stainless steel shell side, 316
stainless steel tube side, 1/2" O.D. tubing size, 98
sq.ft (89.1 sq.m) heat transfer area.
Shell
Tube
Design
Pressure
75 psig & F.V.
75 psig
Design
Temperature
320ºF
320ºF
Min. Design Metal
Temp 32ºF
32ºF
At
Pressure:
75
psig
75 psig
- Vapour Chamber 2'0"
diameter x 2'0" side of conical bottom head, 24" ID
x approx. 48" high stainless steel 304 including sight
glass.
Design
Pressure
75 psig
Design
Temperature
320ºF
Min. Design Metal
Temp 32ºF
At
Pressure:
75 psig
All built in accordance with ASME Code and TEMA Standards
and also National Boiler Board "U " stamped.
Mounted on a common frame and loaded on aluminum tractor trailer
including railings so it can be used as a mobile plant.
Still required is re-circulation pump, vacuum pump and instrumentation.
Typical set-up as indicated on P&ID below.
|
|
|
|
|

Overall view of plant
|
|

Close up of Evaporator
|
|

Close up of Evaporator and Condenser
|
|

Close up of plant
|
|
|
|
|
|